FOX System
Fixed-speed Digital Motor Control System
——

                                                              


l Local controls: 8x3-position travel direction switch for easy local control

l Emergency stop: Meet SIL3 standards, include dual power supply contactors with a self-healing feature

l Control mechanism: Multiple units to be controlled by a single go button

l Power supply quality inspection: Automatic phase reversal detection, supply voltage monitoring, power supply connections, and frequency assessment

l Optional upgrades: Ethernet connectivity, position encoder integration, limit switch compatibility, and KiloCel connectivity

l Motor and direction control: 4 MCBs and 16 direction contactors with interlocking and mirror contact feedback

l Protection features: RCD protection and motor current protection

l Feedback display: A 7" IPS screen for real-time feedback display





Weighing System
——

                                                              


                                       


                     l Load cell: Shackle form

                     l Safety factor: High safety factor, provide 10x safety protection

                     l Measuring range: 1T~5T, 150%F.S overload capacity

                     l Connections: Composite power supply, communication cables, single point and Daisy chain

                     l Controller: 1 controller controls up to 100 load sensors

                     l Monitoring interface: Multi-region monitoring page and various monitoring interfaces

                     l Data recording: Real time load monitor and real-time running data recording

                     l Safety protection: Protection of alarm, underload, and overload









IAC Distributed Control System
——
TÜV Rheinland SIL3 Certified



                                    l Safety certification: TUV Rheinland certified SIL3 safety level

                                    l Control object: Chain hoist, lifting platform, track car, screen, etc.

                                    l Motor: Servo motor, 3-phase asynchronous motor

                                    l Redundancy: Ring network, multi-console

                                    l External trigger: DMX, LTC time code

                                    l Direct nodes: 1 control system to 128, and 1 console to 1024

                                    l Safety protection: Over range, limit, under&overload, speed&position deviation

                                    l Control mode: Speed closed loop, position closed loop;

                                    l Encoder: 2 encoders: incremental & absolute