TOURING SYSTEM
Touring performances require equipment to be built quickly in a building block fashion, which requires more flexibility and safety than theater equipment.
——



           l Modular drives

           l Software control console based on project management principles

           l Shackle-type load cells

           l Power box with safety emergency stop link and leakage bypass



System Flowchart


l Consoles can be cascaded for redundancy backup

l The main control unit can be expanded to multiple levels, with the console capable of controlling a large number of devices

l A single main control unit supports 96 drivers

l Safety emergency stop linkage design

l Compatible with various types of equipment such as chain hoists, winches, lifting platforms, rotating platforms, and retractable screens

l Supports equipment safety grouping, synchronous grouping, and object grouping functions

l Programming software supports multi-command and multi-step programming modes


IAC 5 Series Diver

l Built-in local operation panel for convenient local control

l Motor power adaptation, e.g., a 3KW drive unit can adapt to an internal 3KW motor

l High-speed industrial Ethernet communication between drive units and main control

l Power and communication cables can use a daisy-chain connection method for easy wiring

l Integrated load sensor interface for nearby load sensor signal collection, providing overload and underload protection

l Industry-standard power connectors with one input and one output

l Multi-functional Harting connector for motor connections, including signals for motor, brake, limit, and encoder

l Dual encoder design, capable of connecting one absolute and one incremental encoder

l Standard clamps suitable for various TRUSS connections

l Designed according to DIN56950 and EN17206 standards

KiloCell Load Cells


l Composed of a load-bearing shackle and an integrated load cell with an LED display, allowing real-time weight monitoring and protection setting

l Integrated design of shackle, load cells, and processor for easy installation and use

l 8x safety factor

l Communication interface uses XLR5PIN, supporting single-point or daisy-chain connections, with a single link supporting up to 16 units

l Power supply: 24VDC

l Communication: CANopen

l Low headroom, optional locking eye model

l Supports 0.5-ton and 1-ton capacities

l Can be used with a driver or independently




PDES System Cabinet

l External power interface: 5 standard CAMLOCK single-pole connectors for power input
l Power supply mode: TN-C or TN-S, rated supply voltage: 380-400VAC (L1+L2+L3+N+PE)
l 8 x 32A three-phase independent Ceeform socket switches
l Integrated emergency stop (bypass) interface using XLR 5PIN, cascading emergency stop interface using XLR 3PIN, integrated emergency stop button
l Equipped with circuit breakers and leakage protection devices, with bypass capability for the leakage protection device
l Network interface to console: 2 RJ45 Ethernet ports, 2 fiber optic ports (single-mode dual-core)
l 7 EtherCAT interface data outputs to drive units, communication rate of 100Mbps, scanning cycle for 100 drive units less than 1ms
l Single PDES cabinet supports up to 128 devices
l Supports cascading of up to 16 main control units
l Single main control unit supports connection of up to 96 drive units
Aurora Pro Console


l Dual 17-inch touch screen human-machine interface for monitoring and operation

l Equipped with multiple interfaces including Ethernet, fiber optic, USB, etc.

l Integrated, networked console with emergency stop button and 3D mouse; multifunctional panel capable of operating 6 scenes simultaneously

l Supports DMX512 communication protocol

l Supports LTC timecode, allowing scenes to be triggered by external timecode

l Dual-console redundancy backup; if one console fails, the system seamlessly switches to the other

l Built-in 5-minute UPS to save data and perform an orderly shutdown in case of external power failure




Control Software

l Block-style programming method

l Device topology selection with WYSIWYG (What You See Is What You Get)Multi- command programming
l Flexible programming modes including repertoire + channel + scene + steps + multi-command
l Safety grouping based on objects
l Multi-view device monitoring mode
l Device management with parameter settings such as software limits and position scaling
l User management with permission levels for different users
l Log management for operation logs, alarm logs, and other information
l System diagnostics for displaying and diagnosing the status of individual drives and the overall system